Agri Products Edu Products

Gamma Spectroscopy & Compton Effect

SKU Item Code: SN1038 Category

Principle and Working:

Additional information

Salient Features

  • Complete spectroscopy system designed for nuclear science.
  • UCS-30 contains MCA (Multi-Channel Analyser) with an internal pre-amplifier, computer controlled amplifier, high voltage, upper and lower level discriminators, ADC, and Multichannel Scaling for half-life and decay studies
  • UCS-30 is operated using a computer (PC or Mac) via a USB connection.
  • It includes Mossbauer interface and preamplifier power output (±12 V) for connecting detectors with external preamplifiers such as proportional counters and CdZnTe probes.
  • Sodium iodide (NaI) scintillator is primarily used for detecting low levels of gamma radiation.

Objectives

  • Detecting Gamma Radiation with a scintillation counter.
  • Recording and calibrating Gamma Spectrum.
  • Identifying & determining activity of radioactive samples
  • Qualitative observation of the Compton Effect.
  • Energy calibration.
  • Detector Energy Resolution.
  • Pair Production and Annihilation.
  • Counting Statistics.
  • Absorption of Gamma radiation.
  • Multichannel scaling and Half Life.

Technical Data

  • UCS 30 : Input BNC connector, Output MHV connector, High voltage 0 to +2048 volts,computer controlled in 2 volt increments, USB connection, AC Power adapter.
  • NaI Detector : For detecting low levels of gamma radiation. Dimension 38.1 mm x 38.1 mm (diameter x thickness), NaI crystal coupled to a photomultiplier tube.
  • Lead shield : To ship and store higher activity sources up to 1″ diameter disk sources. Exterior Dimensions 2.25” x 3.6”, Interior Dimensions 1.25” x 2.65”, Wall thickness 0.5”, Weight 2.13 kg.
  • Sources (order separately): Sealed disk (1″ diameter),Ba-133 1 μCi (37 kBq), Cd-109 1 μCi (37 kBq), Co-57 1 μCi (37 kBq), Co-60 1 μCi (37 kBq),Cs-137 1 μCi (37 kBq), Mn-54 1 μCi (37 kBq), Na-22 1 μCi (37 kBq), Mixed “Unknown”, Cs-137, 0.5 μCi (18.5 kBq), Zn-65, 1 μCi (37 kBq)

Scope of Delivery

  • 1 Universal Computer Spectrometer with software (UCS30)
  • 1 NaI(Tl) Scintillation detector with stand
  • 1 USB Cable
  • 2 BNC Cable (for data collection and High Volatge)
  • 1 Set of 8 gamma sources (order separately)
  • 1 Set of 20 Absorbers
  • 1 Lead Shield for radioactive sources
  • 1 Lead Shield for Detector Holder
  • 1 Instuction Manual (CD Version)
Fill out the Form and Download the Product List